|   | 1 | Down Main Home | 
|   | 2 | Down Main Inner Home to Gaer Branch - 30 - Released by N 515 | 
|  | 3 | (Space) | 
|  | 4 | (Space) | 
|   | 5 | (Spare. Formerly Down Main Starting - 45) | 
|   | 6 | (Spare. Formerly Down Main Advanced Starting) | 
|  | 7 | (Space) | 
|  | 8 | (Space) | 
|   | 9 | Down Main Inner Home to Cardiff Curve - 52 31 30 | 
|  | 10 | (Space) | 
|  | 11 | (Space) | 
|   | 12 | Down Cardiff Curve Home - 52 31 | 
|   | 13 | (Spare. Formerly Down Goods Inner Home to Down Through Sidings - 53 52 31) | 
|   | 14 | Disc Down Cardiff Curve Home to Down Siding - 53 54 31 | 
|   | 15 | Interlocking Lever for Backing Along Down Cardiff Curve to L.O.S. (Out of use?)
 | 
|   | 16 | Down Cardiff Curve Starting - Slotted by N638 | 
|  | 17 | (Space) | 
|   | 18 | (Acceptance Lever from Lime Kiln Sidings. Bolted Normal.) | 
|   | 19 | (Interlocking Lever with Rogerstone Ground Frame. Bolted Normal.) | 
|  | 20 | (Space) | 
|   | 21 | Disc for 40B - 40 26 | 
|  | 22 | (Space) | 
|  | 23 | (Space) | 
|   | 24 | (Spare. Formerly Down Main Detonators Off - On) | 
|   | 25 | (Spare. Formerly Down Cardiff Curve Detonators Off - On) | 
|   | 26 | Disc at 27B - 30 27 -or- 52 31 30 27 -or- 67 - Released by N 515 | 
|   | 27 | Mains - +Over | 
|   | 28 | (Spare. Formerly Disc for 27A - 27 -or- 54 53 31 27) | 
|   | 29 | Disc Backing Up Main - 26 | 
|   | 30 | F.P.L for 31 - Nil -or- 31 | 
|   | 31 | Down Main Facing - Cardiff Curve | 
|  | 32 | (Space) | 
|  | 33 | (Space) | 
|  | 34 | (Space) | 
|  | 35 | (Space) | 
|  | 36 | (Space) | 
|  | 37 | (Space) | 
|  | 38 | (Space) | 
|  | 39 | (Space) | 
|   | 40 | Up Main Facing - Machen Quarry | 
|  | 41 | (Space) | 
|  | 42 | (Space) | 
|   | 43 | Disc for 40A - 40 | 
|  | 44 | (Space) | 
|  | 45 | (Space) | 
|  | 46 | (Space) | 
|  | 47 | (Space) | 
|  | 48 | (Permanent Space / Frame Covered Over) | 
|  | 49 | (Permanent Space / Frame Covered Over) | 
|  | 50 | (Permanent Space / Frame Covered Over) | 
|  | 51 | (Permanent Space / Frame Covered Over) | 
|   | 52 | F.P.L for 54 - Nil -or- 54 | 
|   | 53 | Down Siding Safety - 54 | 
|   | 54 | Down Cardiff Curve Facing - Down Siding | 
|   | 55 | (Spare. Formerly Down Relief Goods Facing - Down Main Goods) | 
|   | 56 | Disc Down Siding Starting - 27 31 53 | 
|  | 57 | (Space) | 
|  | 58 | (Space) | 
|  | 59 | (Space) | 
|   | 60 | (Spare. Formerly Disc Backing from Down Through Siding - 53 31 28) | 
|   | 61 | (Spare. Formerly Disc at 64A - 64 62 -or- 62) | 
|   | 62 | (Spare. Formerly Up Goods From Up Main - From Cardiff Curve) | 
|  | 63 | (Space) | 
|  | 64 | (Permanent Space) | 
|  | 65 | (Space) | 
|   | 66 | Disc for 67A - 67 | 
|   | 67 | Cardiff Curve - +Over - 54 (0)
 | 
|   | 68 | Disc at 67B - 67 -or- 27 31 | 
|  | 69 | (Space) | 
|  | 70 | (Space) | 
|  | 71 | (Space) | 
|   | 72 | (Spare / Maintain Interlocking Bolted Normal) | 
|   | 73 | (Spare) | 
|   | 74 | (Spare) | 
|   | 75 | Down Main Facing - Up Main | 
|   | 76 | Up Main Advanced Starting - 75 | 
|   | 77 | Up Main Starting | 
|   | 78 | Up Cardiff Curve Starting | 
|   | 79 | Up Cardiff Curve Shunt Ahead | 
|   | 80 | Up Cardiff Curve Inner Home | 
|   | 81 | Up Cardiff Curve Home - Slotted by N 015 ([sic '015'])
 | 
|   | 82 | (Spare. Formerly Up Relief Goods Home - 63 64) | 
|  | 83 | (Space) | 
|   | 84 | Up Gaer Branch Home - 27 | 
|   | 85 | Acceptance Lever from Gaer | 
|  | 86 | (Space) | 
|  | 87 | (Permanent Space) | 
|  | 88 | (Space) | 
|  | 89 | (Space) | 
|  | 90 | (Space) | 
|  | 91 | (Space) | 
|  | 92 | (Permanent Space) | 
|  | 93 | (Permanent Space) | 
|  | 94 | (Space) | 
|  | 95 | (Space) | 
|  | 96 | (Space) | 
|  | 97 | (Space) | 
|  | 98 | (Space) | 
|  | 99 | (Space) | 
|  | 100 | (Space) |