| 1   | Down Main Distant - 2 3 4 5 6 | 
    | 2   | Down Main Home - 11 -or- 19 14 12 11 | 
    | 3   | Down Main Inner Home - 11 | 
    | 4   | Down Main Starting | 
    | 5   | Branch Starting to Down Main - 33 34 36 37 28  (No Line Clear required as Burngullow Panel in Par Box.) | 
    | 6   | Down Main Advanced Starting | 
    | 7   | Down Main Inner Home to Branch - 19 12 11 15 | 
    | 8   | Down Branch Starting - 43 28 | 
    | 9   | Down Branch Advanced Starting - 43 | 
    | 10   | Disc Down Main Inner Home to Siding - 23 12 11 15 | 
    | 11   | F.P.L. for 12B - Worked to Maintain Locking | 
    | 12   | Mains Facing + Over | 
    | 13   | F.P.L for 12A - Worked to Maintain Locking | 
    | 14   | F.P.L.'s for 19 and 23B - Worked to Maintain Locking  ([sic apostrophe]) | 
    | 15   | Disc at 19 - [] [] 34 14 -or- 34 36 37 28 19 14 -or- 37 29 28 19 14 -or- 43 28 19 14 -or- 23 14  ([] where two numbers have been patched over from the first route. 29 seems to be missing from the second route.) | 
    | 16   | Disc at 31A | 
    | 17   | Down Main Home to Down Goods Loop - 18 | 
    | 18   | Down Main Facing - Down Goods Loop | 
    | 19   | Up Main to Down Branch Facing - Down Branch | 
    | 20   |  (Spare) | 
    | 21   | Disc Up Main Starting or to Down Main L.O.S. - 13 | 
    | 22   |  (Spare) | 
    | 23   | Down Branch Facing - Up Siding - 19 | 
    | 24   | Disc Up Branch Starting to Up Main or Down Main L.O.S. - 13 19 | 
    | 25   |  (Spare) | 
    | 26   | Disc Down Branch Starting to Up Main L.O.S. or Refuge Siding - 34 36 37 28 -or- 37 29 28 | 
    | 27   |  (Spare) | 
    | 28   | F.P.L for 29A | 
    | 29   | Down Branch Facing - Refuge Siding | 
    | 30   | Down Goods Starting to Down Main - 31 | 
    | 31   | Down Goods Loop Facing - Down Main | 
    | 32   | Disc for 32A - 13 23 | 
    | 33   | Mains - +Over | 
    | 34   | F.P.L for 33A | 
    | 35   | Disc at 33B - Nil -or- 13 37 | 
    | 36   | Up Main Facing - Up Branch - 29 | 
    | 37   | F.P.L.s for 36 | 
    | 38   | Disc Up Main Home or to Up Branch - 13 37 | 
    | 39   |  (Spare) | 
    | 40   | Disc for 41 - 41 | 
    | 41   | Loop Safety | 
    | 42   | Up and Down Branch Facings - +Over | 
    | 43   | F.P.L.s for 42 - Worked to Maintain Locking | 
    | 44   | Disc Up Branch Home to Up Siding - 23 13 41 43 -or- 41 43 | 
    | 45   |  (Spare) | 
    | 46   | Up Branch Calling On - 42 43 | 
    | 47   | Disc Backing from Up Main - 34 | 
    | 48   | Up Refuge Safety - 29 | 
    | 49   | Disc for 48 - 13 48 | 
    | 50   | Up Main Home to Up Branch - 13 36 37 | 
    | 51   | Up Main Advanced Starting  (No Line Clear required as PR100 IBS ahead) | 
    | 52   | Branch Starting to Up Main - 13 19 | 
    | 53   | Up Branch Home - 13 42 43 | 
    | 54   | Up Main Starting - 13 | 
    | 55   | Up Main Home - 13 27 | 
    | 56   | Up Main Distant - 55 54 51 | 
|   | 100   | Up Main I.B.S. Home & Distant - Line Clear  (Switch on Block Shelf.) |